• geo.be Metadata Catalog
  •  
  •  
  •  

synoptische Beobachtungen

The SYNOP data of RMI contain the observations of the synoptic network, currently consisting of 29 stations, 13 of which are owned by RMI. The other stations belong to MeteoWing (8 stations), Skeyes (7 stations). There is also 1 foreign station.

All SYNOP data is given in Universal Time! (local time winter = UT +1; local time summer = UT + 2)

Parameters:

1. Precipitation: PRECIP_QUANTITY + PRECIP_RANGE

2. Temperature: TEMP + TEMP_MIN + TEMP_MAX + TEMP_GRASS_MIN

3. Wind: WIND_SPEED + WIND_SPEED_UNIT + WIND_DIRECTION + WIND_PEAK_SPEED

4. relative humidity: HUMIDITY_RELATIVE

5. weather type: WEATHER_CURRENT

6. air pressure: PRESSURE of PRESSURE_STATION_LEVEL

7. sunshine duration: SUN_DURATION_24H

8. Global radiation: SHORT_WAVE_FROM_SKY_24HOUR

9. Total cloudiness: CLOUDINESS

Simple

Datum (Überarbeitung)
2024-10-02
Identifikator
RMI-be / synop
Bearbeitungsstatus
Kontinuierliche Aktualisierung
Ansprechpartner
  Königliche Meteorologische Institut
Eigentümer / Datenherr
  Königliche Meteorologische Institut
Überarbeitungsintervall
Kontinuierlich
GEMET - INSPIRE themes, version 1.0
  • Meteorologisch-geografische Kennwerte
Keywords Schlüsselwörter
  • Reporting INSPIRE
  • federal government
  • observation
  • synoptic
  • cloudiness
  • visibility
  • wind speed
  • wind direction
  • gusts
  • temperature
  • dew point
  • humidity
  • pressure
  • weather type
  • precipitation
  • snow
  • sun duration
Spatial scope
  • National
Zugriffseinschränkungen
Benutzerdeifinierte Einschränkungen
Andere Einschränkungen
Öffentliche Zugang nicht beschränkt
Nutzungseinschränkungen
Benutzerdeifinierte Einschränkungen
Andere Einschränkungen

Creative Commons Namensnennung 4.0 International (CC BY 4.0)

Dies ist eine allgemeinverständliche Zusammenfassung der Lizenz (die diese nicht ersetzt).

Sie dürfen:

Teilen — das Material in jedwedem Format oder Medium vervielfältigen und weiterverbreiten

Bearbeiten — das Material remixen, verändern und darauf aufbauen und zwar für beliebige Zwecke, sogar kommerziell.

Unter folgenden Bedingungen:

Namensnennung — Sie müssen angemessene Urheber- und Rechteangaben machen, einen Link zur Lizenz beifügen und angeben, ob Änderungen vorgenommen wurden. Diese Angaben dürfen in jeder angemessenen Art und Weise gemacht werden, allerdings nicht so, dass der Eindruck entsteht, der Lizenzgeber unterstütze gerade Sie oder Ihre Nutzung besonders.

Keine weiteren Einschränkungen — Sie dürfen keine zusätzlichen Klauseln oder technische Verfahren einsetzen, die anderen rechtlich irgendetwas untersagen, was die Lizenz erlaubt.

Sicherheitseinstufung
Unbeschränkt
Räumliche Darstellungsart
Vektor
Sprache
English
Thematik
  • Atmosphäre
N
S
E
W


Anfangszeitpunkt
1952-01-01T00:00:00
Code
EPSG:4258
Abgabeformat
  • CSV ( 1.0 )

  • GML ( 2 )

  • GML ( 3.1 )

  • GML ( 3.2 )

  • GeoJSON ( 1.0 )

  • KML ( 1.0 )

  • Shapefile ( 1.0 )

Online
RMI opendata portal ( WWW:LINK-1.0-http--link )

RMI opendata portal

Online
synop:synop ( OGC:WMS-1.3.0-http-get-capabilities )

WMS 1.3.0 getCapabilities document

Online
synop:synop ( OGC:WFS-1.0.0-http-get-capabilities )

WFS 1.0.0 getCapabilities document

Online
FTP directory to download BUFR synop messages ( WWW:DOWNLOAD-1.0-ftp--download )

FTP directory to download BUFR synop messages

Online
HTTP repository to download BUFR synop messages ( WWW:LINK-1.0-http--link )

HTTP repository to download BUFR synop messages

Online
Dokumentation ( WWW:LINK-1.0-http--link )

Dokumentation

Bezugsebene
Datenbestand
Andere
dataset

Konsistenz des Wertebereichs

Testverfahren
INSPIRE Conformity

Konformitätsergebnis

Datum (Publikation)
2010-12-08
Erklärung
See the referenced specification
Bestanden
Nein
Erläuterung

SYNOP data are first subjected to an automatic quality control where we check for missing values and if the values are within certain physical limits. This automatic QC is followed by a manual QC performed by RMI staff members.

Different instruments are calibrated by RMI in its calibration laboratory.

The TEMPERATURE sensors are calibrated by comparing the pt100 sensor of the station with the pt25 reference sensor of the calibration lab (which are calibrated by the national metrology lab). They are compared in a thermostatic bath which contains an “azeotropic mixture of propyleenglycol and water” (50-50%). This allows the same bath and mixture to be used for the entire temperature range (-25°C to 35°C). The calibration is performed at 6 fixed temperatures: -25°C, -10°C, 0°C, 10°C, 20°C and 35°C.

The calibration of the PRESSURE sensors is performed using a balance system with two pumps (for under and over pressure) and three reference sensors: a recent one (rpm4) and two older ones (paroscientific) in an automated way with 3 up and down cycles within the pressure range 810-1050hPa, with a calibration every 30hPa.

The calibration of the HUMIDITY sensors is performed in a climate closet (Weiss) by varying the temperature and relative humidity and by using a chilled mirror sensor.

Metadatensatzidentifikator
RMI_DATASET_SYNOP XML
Sprache
English
Hierarchieebene
Datenbestand
Datum
2024-10-02
Ansprechpartner
  Königliche Meteorologische Institut
http://www.meteo.be
 
 

Overviews

Räumliche Ausdehnung

N
S
E
W


Keywords Schlüsselwörter


Provided by

Not available


  •  
  •  
  •